Naga MounikaDrug Product · Validation · CMC
Menu
Working document

Chain of Identity Verification Log

A plug-and-play log for verifying and recording a single patient's chain of identity through every handoff of an autologous cell therapy process, collection through courier dispatch, in-process manufacturing, and infusion, so an identity gap is caught at the handoff rather than discovered later in a record review, with a filled sample row.

Document typeLog
Topic areaProcess Validation
LevelIntermediate
UpdatedSeptember 2026
How to use this document

Copy the template below into your quality system. Replace every <<FILL: ...>> placeholder with your company, system, and process specifics, then route it through your own document control, review, and approval. The filled specimen shows one worked example; adapt the numbers and scope to your operation and verify each cited regulation or standard against the current source before you rely on it.

This is a generic, originally worded starting point. It contains no confidential, proprietary, or employer material, it is drafted with AI assistance and reviewed, it is not legal or compliance advice, and adopting it does not by itself create or prove compliance. See the Disclaimer and Terms.

This is a ready-to-use log for verifying and recording a single patient’s chain of identity at every handoff of an autologous cell therapy process: collection, receipt into manufacturing, in-process handoffs between operators or systems, final product labeling, and release for infusion. It exists because an autologous batch has no next lot to fall back on; a chain-of-identity gap is not a paperwork finding to close later, it is a patient safety control that has to be verified in real time, at the moment of each handoff, not reconstructed afterward from a batch record. Replace every <<FILL: ...>> placeholder with your own specifics and route the completed log per your document retention procedure. A worked filled sample row follows.

Purpose

This log records, for every real patient’s <<FILL: product / process name>>, a positive identity verification at each defined handoff point, so that a mismatch is caught and stopped at the handoff where it occurred rather than discovered during a later record review or, worse, after infusion.

Scope

Applies to every patient lot of <<FILL: product(s)>> manufactured at <<FILL: site(s)>>, from collection through release for infusion. Out of scope: donor eligibility determination for allogeneic starting material, covered under its own procedure.

Field table

FieldFormatRequiredWho records itWhen
Unique patient identifier (per site coding / privacy procedure)<<FILL: format>>YesCollection site staffAt collection
Starting material / apheresis unique identifier<<FILL: format>>YesCollection site staffAt collection
Two-identifier verification method used at collection (e.g. patient ID plus date of birth, cross-checked against the collection order)TextYesCollection site staff, with a second, independent verifierAt collection
Courier dispatch identifier check: identifiers verified against the collection record before the shipper leaves the collection siteYes/No, verification method (barcode scan preferred over a visual label read alone)YesCollection site staffAt courier dispatch
Manufacturing receipt: identifier match confirmed against collection recordYes/No, verified by two individualsYesReceiving manufacturing staffAt receipt into manufacturing
In-process handoff identifier checks (one row per handoff: vessel-to-vessel, system-to-system, shift-to-shift)Text, handoff description plus Yes/No match confirmationYes, one entry per handoffManufacturing staff at each handoff, with a second verifierAt each in-process handoff
Final product label identifier match confirmed against starting material identifierYes/No, verified by two individualsYesManufacturing / packaging staffAt final labeling
Quality Assurance identity reconciliation across the full record, collection to final labelYes/No, reference to reconciliation recordYesQuality AssuranceBefore release for infusion
Discrepancy identified (if any)Text, cross-referenced to deviation numberAs occursWhoever identifies itAt the point identified
Release disposition<<FILL: released for infusion / held / rejected>>YesQuality AssuranceBefore infusion
Receiving clinical site final bedside identity check confirmedYes/NoYesClinical site staffAt infusion

Instructions

Every handoff listed above requires a positive, two-person identifier match at the moment it occurs; a check performed retrospectively from the batch record after the fact does not satisfy this log’s purpose, because its entire function is catching a mismatch before the next step happens, not documenting one after the process has moved on. Do not proceed past a handoff with an unresolved identifier mismatch; stop and initiate a deviation immediately. The courier dispatch check should use a method that does not rely on a single visual read of a printed label, a barcode scan against the collection record is preferable, because two patients collected on the same day with visually similar labels can otherwise be swapped in a way a label-only glance will not catch. Quality Assurance’s end-to-end reconciliation in the second-to-last row is not a repeat of the individual handoff checks, it is an independent, full-record review confirming every recorded check is present, complete, and consistent before the release decision is made. For the cold chain shipping controls that run alongside this identity check on the same shipment, chain of custody, dispatch conditions, temperature qualification, see cold chain qualification for cryoshippers and dry-vapor shippers and the paired cryoshipper dispatch and chain-of-custody log; the two logs run together at dispatch, one for custody and one for identity, and neither substitutes for the other.

Retention

Retain this log per <<FILL: site document retention procedure and retention period, tied to the product's patient medical record retention requirement>>, retrievable alongside the batch record and the release decision for the specific patient lot it documents.

Filled sample row

FieldEntry
Patient identifierPer site coding procedure, cross-referenced to clinical record
Starting material identifierAPH-2026-0341
Collection verificationTwo-identifier check (patient ID plus date of birth) against the collection order, confirmed by collection nurse and an independent second verifier
Courier dispatch checkYes, barcode scan of the shipper label against the collection record, confirmed before the courier left the collection site
Manufacturing receipt matchYes, confirmed by receiving technician and a second technician against APH-2026-0341
In-process handoffsHandoff 1, isolation vessel to formulation vessel: Yes, confirmed by two operators. Handoff 2, formulation to fill: Yes, confirmed by two operators
Final label matchYes, confirmed by packaging technician and a second verifier against APH-2026-0341
QA reconciliationYes, reconciliation record REC-2026-0341, reviewed by Quality Assurance, full record consistent from collection through final label
DiscrepancyNone identified
Release dispositionReleased for infusion
Bedside identity checkYes, confirmed by clinical site staff at infusion

Common findings this log prevents

  • An identity check described in the batch record narrative with no independent second verifier named, so the check cannot be confirmed as a true two-person verification.
  • An in-process handoff with no identity check recorded at all, discovered only when Quality Assurance’s end-to-end reconciliation is performed, by which point the product has already moved past that step.
  • A discrepancy identified but not cross-referenced to a deviation number, so its resolution cannot be traced.
  • Release for infusion documented with no explicit Quality Assurance reconciliation step distinct from the individual handoff checks.
  • A courier dispatch check performed by a single visual read of a printed label, with no barcode or independent cross-check, on a day with more than one similarly labeled patient collection in process.

How to adapt this log

  1. Map every real handoff your process actually has, vessel changes, system changes, shift changes, site-to-site transfers, and add one row per handoff; a handoff omitted from this log is a handoff this control cannot protect.
  2. Define the two-identifier method explicitly for your process (patient ID plus date of birth, or your own site standard) and use it consistently at every check, not a different method at each step.
  3. Tie the retention period to your product’s actual patient medical record retention requirement, not a generic default.
  4. Route any discrepancy immediately into your deviation process; do not let this log’s own “Discrepancy” field become the only record of an identity mismatch.