Routine Batch Filter Integrity Test Log

A plug-and-play running log for post-use and, where applicable, PUPSIT filter integrity test results across routine batches, with field definitions, a filled sample row, and retention guidance.

Document typeLog
Topic areaDrug Product
LevelIntermediate
UpdatedSeptember 2026
How to use this document

Copy the template below into your quality system. Replace every <<FILL: ...>> placeholder with your company, system, and process specifics, then route it through your own document control, review, and approval. The filled specimen shows one worked example; adapt the numbers and scope to your operation and verify each cited regulation or standard against the current source before you rely on it.

This is a generic, originally worded starting point. It contains no confidential, proprietary, or employer material, it is drafted with AI assistance and reviewed, it is not legal or compliance advice, and adopting it does not by itself create or prove compliance. See the Disclaimer and Terms.

This is a ready-to-use running log for recording physical integrity test results on the final sterilizing filter for every routine batch: the post-use test always, and the pre-use, post-sterilization (PUPSIT) result where it is performed. Replace every <<FILL: ...>> placeholder with your own specifics. A filled sample row follows.

Instructions

Log the integrity test result for every batch’s final sterilizing filter, referencing the validated production specification set in the filter validation protocol. A result at or above the validated limit is an integrity test failure regardless of whether the batch’s sterility test later passes; do not wait for the sterility result before opening a deviation. Retain per <<FILL: document retention period>>.

Field definitions

FieldFormatRequiredWho completes itWhen
Batch number<<FILL>>YesManufacturingAt filtration
Filter lot number<<FILL>>YesManufacturingAt filtration
Wetting fluid used<<FILL: product-wetted or water-wet; must match the validated basis>>YesManufacturingAt test
PUPSIT performed?Yes / No, per the current PUPSIT risk-based justificationYesManufacturingBefore product contact
PUPSIT result<<FILL: reading and pass/fail>>Yes, if PUPSIT performedManufacturingBefore product contact
Post-use test method<<FILL: bubble point / diffusive flow / water intrusion>>YesManufacturingAfter filtration
Post-use test reading<<FILL>>YesManufacturingAfter filtration
Validated specification<<FILL: reference the filter validation protocol>>YesManufacturingAt test
Pass/Fail<<FILL>>YesManufacturingAt test
Deviation reference, if failed<<FILL>>Yes, if applicableQuality AssuranceAt disposition
QA reviewInitials and dateYesQuality AssuranceBatch release

Log

BatchFilter lotWetting fluidPUPSIT?PUPSIT resultPost-use methodPost-use readingSpecPass/FailDeviation refQA review
<<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>><<FILL>>

Filled specimen

Sample rows from an example gene therapy drug product fill campaign. Company, product, and numbers are illustrative.

BatchFilter lotWetting fluidPUPSIT?PUPSIT resultPost-use methodPost-use readingSpecPass/FailDeviation refQA review
ATX-DP-0231FL-88214Product-wettedNo, per PUP-2026-02N/ADiffusive flow9.8 mL/minLess than or equal to 12 mL/minPassN/AJS, 2026-08-14
ATX-DP-0232FL-88215Product-wettedNo, per PUP-2026-02N/ADiffusive flow14.6 mL/minLess than or equal to 12 mL/minFailDEV-2026-0209JS, 2026-08-15
ATX-DP-0233FL-88216Product-wettedNo, per PUP-2026-02N/ADiffusive flow8.1 mL/minLess than or equal to 12 mL/minPassN/AJS, 2026-08-16

Batch ATX-DP-0232’s post-use test failure opened DEV-2026-0209 immediately, before the batch’s sterility result was available, consistent with the rule that an integrity test failure stands on its own regardless of a later sterility pass. The investigation traced the elevated reading to a filter handling error, not a manufacturing defect, and the batch was rejected rather than released on the strength of a passing sterility test alone.

Common inspection findings this log prevents

  • A post-use integrity test failure not investigated because the batch’s sterility test came back clean.
  • A wetting fluid recorded as “water” when the validated basis assumed product-wetted testing, or vice versa, invalidating the comparison to the specification.
  • PUPSIT status not recorded per batch, so it cannot be confirmed the current risk-based justification was actually followed in practice.
  • Gaps in the log where a batch’s integrity test result was never transcribed from the raw instrument printout.
  • QA review recorded as complete with no initials or date tied to a specific reviewer.

How to adapt this log

  1. Set your retention period and reference your current filter validation protocol and PUPSIT justification document numbers.
  2. Make the wetting fluid field mandatory; a mismatch between validated basis and actual test fluid is a real, not cosmetic, defect.
  3. Require immediate deviation initiation on any Fail, decoupled from the sterility test timeline.
  4. Periodically trend the post-use readings across batches, not just check pass/fail, to catch a filter lot or process drift before it produces an outright failure.
  5. Confirm the log’s field set matches what your current filter validation protocol and PUPSIT justification actually require before first use.